IB Chemistry SLTopic 8 — Collecting and Processing DataInternal assessmentPractical skill~12 min read
Collecting Data
This is the doing part, and everyone assumes it is the easy part. Marks are almost never lost here because the chemistry was hard. They are lost because a number was written down without its last zero, or because something went wrong and nobody wrote it down.
📚 What you need to know
Design your raw data table before you start, not while the reaction is happening.
Raw means raw. Only numbers you actually read off an instrument. No calculations.
Units and uncertainties go in the column headers, never next to the numbers.
Record every reading to the precision of the instrument, trailing zeros included.
Collect five values of the independent variable with three trials each.
Qualitative observations are evidence. You will need them to explain your result.
If something goes wrong, write it down and act. Hiding it is what costs marks.
Design the table before you touch anything
Once the stopwatch is running you have no attention left for deciding which columns you need. So the table is built the day before, printed out, and taken into the lab with empty boxes waiting to be filled.
A table that will earn marks has four things: a title specific enough that someone can tell what the experiment was, one clearly labelled column for the independent variable, columns for every repeat of the dependent variable, and headers that carry the units and the uncertainty.
Every cell in this table is a number a person read off a scale. That is the test for whether something belongs in a raw data table.
Most students put the titre straight into the raw table, and most teachers let it go. But strictly the titre is calculated, so it sits more comfortably in your processed table. Recording both burette readings also protects you: if you make a subtraction slip, the original numbers are still there to rescue you.
Record to the precision of the instrument
This is the single most common place students throw marks away, and it takes one second to fix. The rule is that your reading must show every digit the instrument can give you — including a zero at the end, which feels pointless and is not.
There is a second reason to care. On a 0.20 g sample, an uncertainty of ±0.01 g is 5%; on a 1.50 g sample it is only 0.67%. Small masses are expensive.
Instrument
How it is written down
Uncertainty to quote
Burette graduated every 0.1 cm3
two decimal places ending in 0 or 5, e.g. 21.80 cm3
±0.05 cm3 per reading
Volumetric pipette, 25.00 cm3
the stated volume, 25.00 cm3
±0.03 cm3 (check the glass)
Measuring cylinder, 50 cm3
one decimal place, e.g. 24.5 cm3
±0.5 cm3
Digital balance reading to 0.01 g
two decimal places, e.g. 1.50 g
±0.01 g
Digital thermometer reading to 0.1 °C
one decimal place, e.g. 21.4 °C
±0.1 °C
Stopwatch displaying 0.01 s
two decimal places, e.g. 42.61 s
±0.3 s or so — see below
The stopwatch is the honest exception, and saying so out loud impresses an assessor. The display gives you hundredths of a second, but your thumb does not. Human reaction time is roughly 0.2–0.3 s at each end, so the real uncertainty in a hand-timed result is much larger than the display suggests. Quote the uncertainty your method deserves, not the one the screen offers.
Raw means raw
The raw table is the evidence. If you write only the answers you have already worked out, you have handed in a conclusion and asked to be trusted. Nobody can check a titre of 21.55 cm3; anybody can check 21.70 minus 0.15.
The same rule catches a subtler mistake. If you time a reaction and record only 1/t, you have processed on the fly and the original times are gone. Write down what the instrument said. Turn it into something else in the next section, in daylight, with a calculator.
Qualitative observations are evidence
Qualitative data is everything you noticed but did not measure. Students treat it as a decorative sentence at the bottom of the page. It is actually the thing that will rescue your evaluation, because it is the only evidence you have about why a number came out wrong.
Colour changes — the shade at the endpoint, and how sharply it arrived.
Effervescence — how vigorous, and when it stopped.
Precipitates — colour, and whether the mixture went cloudy or grainy.
Smells — noted from a safe distance, never by leaning in.
Heat — the flask warming or cooling in your hand.
The state of your reactants — a dull grey coating on magnesium ribbon, a solid that had clearly absorbed water.
Here is that last one paying off. Suppose your first trial with magnesium is much slower than the rest. If you wrote “the ribbon looked dull and grey before it was added”, you can now argue that an oxide layer had to be removed before the acid could reach the metal. Without that sentence, the slow trial is just an unexplained number.
When the experiment fights back
Something will go wrong. That is not the problem. Pretending it did not is the problem, and it is also the easiest thing in the world for an assessor to spot, because the data stops making sense.
🧩 What to do the moment it goes wrong
Notice. Look up from the apparatus and name what just happened.
Write it down now, in the lab book, while you can still remember the detail.
Respond — dilute the acid, run an extra trial, change the timing point.
Report it in your method, saying what you changed and why you changed it.
The chain only breaks at step two. Everything after it depends on there being a written note made at the time, rather than a memory reconstructed a fortnight later.
What happens
What to do about it
The reaction is over almost instantly
Dilute a reactant or cool the mixture until the time is long enough to measure, then say in the method that you did and why.
The reaction is far too slow to time
Raise the concentration, warm the mixture or increase the surface area — and check the change has not broken one of your controlled variables.
One trial is wildly out of line
Keep it in the raw table. Run a fourth trial. You will exclude the outlier later, but only after you have justified it.
The endpoint colour creeps in slowly
Note exactly what you judged the endpoint to be, and use the same judgement every time. This becomes a real limitation in your evaluation.
WORKED EXAMPLE
A student’s raw data table contains one row: “Titre 3 = 21.5 cm3 (±0.1)”. Identify three separate faults and write the row out correctly.
Fault 1: it is not rawA titre is the final reading minus the initial reading, so it has been calculated. Both burette readings should appear instead.Fault 2: wrong precisionA burette is read to two decimal places, with the last digit a 0 or a 5. Writing 21.5 pretends the burette was ten times worse than it is.Fault 3: the uncertainty is in the cellIt belongs in the column header, where it applies to every value in that column at once.raw table row: Trial 3 | 0.30 | 21.80with headers reading “Initial burette reading / cm³ (±0.05)” and “Final burette reading / cm³ (±0.05)”.
WORKED EXAMPLE
A student needs about 0.2 g of magnesium and has a balance reading to 0.01 g. They record “0.2 g”. Explain what is wrong, and suggest one change to the method that would improve the result more than better recording would.
The recording faultThe balance supplied a second decimal place and it was discarded. The mass should be written as 0.20 g.Why it matters numerically±0.01 g on 0.20 g = 5.0% uncertaintyThat single measurement is now the biggest source of uncertainty in the whole experiment.The better fixUse a larger sample. The same balance weighing 1.50 g gives only 0.67% — the uncertainty of the instrument is fixed, so make the quantity bigger.weigh more, and write every digit the balance gives
WORKED EXAMPLE
At 50 °C, three trials give times of 18.9 s, 30.2 s and 19.1 s. Describe exactly what the student should do next, and what they must not do.
What must not happenThe 30.2 s result is not erased and not quietly replaced. Deleting data is the one thing that cannot be recovered from.Step 1: record and noteKeep 30.2 s in the raw table and write a note beside it, for example that the stopwatch was started late because the flask was still being swirled.Step 2: run a fourth trialUnder the same conditions. If it returns about 19 s, you now have three concordant results and one identified outlier.Step 3: leave the decision for laterexclude it when processing, with a written justificationYou are allowed to leave an anomaly out of your mean. You are not allowed to leave it out of your report.
💡 Exam tip
Give the raw table a specific title naming the actual chemicals and concentrations.
Put units and uncertainties in the headers, and nothing but numbers in the cells.
Keep every column to a consistent number of decimal places, trailing zeros included.
Record both burette readings, not just the titre.
Write qualitative observations as you go, not from memory afterwards.
Say openly if you changed something mid-experiment — that is a skill, not a confession.
⚠️ Common mix-up
Dropping trailing zeros, which quietly downgrades your own instrument.
Doing calculations in the raw table, so the original measurements are lost.
Writing units after every number in the body of the table instead of in the header.
Quoting the stopwatch display as the uncertainty, ignoring your own reaction time.
Treating qualitative data as filler instead of the evidence that explains your result.
Deleting an anomaly rather than recording it and justifying its exclusion later.
Up next: Processing Data — you now have a page of honest numbers. The next page turns them into a single result, and carries the uncertainty along with it so the result means something.
Want this explained one-to-one?
Book a free session with an experienced IB Chemistry tutor and get your trickiest topics made simple.