IB Chemistry SL Topic 8 — Collecting and Processing Data Internal assessment Practical skill ~12 min read

Collecting Data

This is the doing part, and everyone assumes it is the easy part. Marks are almost never lost here because the chemistry was hard. They are lost because a number was written down without its last zero, or because something went wrong and nobody wrote it down.

📚 What you need to know

Design the table before you touch anything

Once the stopwatch is running you have no attention left for deciding which columns you need. So the table is built the day before, printed out, and taken into the lab with empty boxes waiting to be filled.

A table that will earn marks has four things: a title specific enough that someone can tell what the experiment was, one clearly labelled column for the independent variable, columns for every repeat of the dependent variable, and headers that carry the units and the uncertainty.

WHAT A RAW DATA TABLE HAS TO CARRYdesigned before the first reading, not tidied up afterwardsTable 1: titration of 25.00 cm³ diluted lemon drink against 0.0500 mol dm⁻³ NaOHTrialInitial burette reading/ cm³ (±0.05)Final burette reading/ cm³ (±0.05)Rough1230.000.150.200.3022.1021.7021.8021.80units and uncertainties sit in the header, never beside the numbersevery value in the body is something you read off the glass yourselfnotice there is no titre column: a titre is a subtractionsubtractions are processing, so they belong in the next table
Every cell in this table is a number a person read off a scale. That is the test for whether something belongs in a raw data table.
Most students put the titre straight into the raw table, and most teachers let it go. But strictly the titre is calculated, so it sits more comfortably in your processed table. Recording both burette readings also protects you: if you make a subtraction slip, the original numbers are still there to rescue you.

Record to the precision of the instrument

This is the single most common place students throw marks away, and it takes one second to fix. The rule is that your reading must show every digit the instrument can give you — including a zero at the end, which feels pointless and is not.

THE SAME MASS, WRITTEN TWO WAYSRECORDED CARELESSLYRECORDED PROPERLY0.2 g0.20 gthe balance displays 0.20so a digit has been droppedon the way to the pagethe trailing zero is datait says the hundredths placewas read, and it was zeronow it reads like a guessthe uncertainty is still ±0.01 gevidence thrown awaythe instrument respecteda trailing zero is a measurement, not decorationdeleting it tells your reader the balance was worse than it was
There is a second reason to care. On a 0.20 g sample, an uncertainty of ±0.01 g is 5%; on a 1.50 g sample it is only 0.67%. Small masses are expensive.
InstrumentHow it is written downUncertainty to quote
Burette graduated every 0.1 cm3two decimal places ending in 0 or 5, e.g. 21.80 cm3±0.05 cm3 per reading
Volumetric pipette, 25.00 cm3the stated volume, 25.00 cm3±0.03 cm3 (check the glass)
Measuring cylinder, 50 cm3one decimal place, e.g. 24.5 cm3±0.5 cm3
Digital balance reading to 0.01 gtwo decimal places, e.g. 1.50 g±0.01 g
Digital thermometer reading to 0.1 °Cone decimal place, e.g. 21.4 °C±0.1 °C
Stopwatch displaying 0.01 stwo decimal places, e.g. 42.61 s±0.3 s or so — see below
The stopwatch is the honest exception, and saying so out loud impresses an assessor. The display gives you hundredths of a second, but your thumb does not. Human reaction time is roughly 0.2–0.3 s at each end, so the real uncertainty in a hand-timed result is much larger than the display suggests. Quote the uncertainty your method deserves, not the one the screen offers.

Raw means raw

The raw table is the evidence. If you write only the answers you have already worked out, you have handed in a conclusion and asked to be trusted. Nobody can check a titre of 21.55 cm3; anybody can check 21.70 minus 0.15.

The same rule catches a subtler mistake. If you time a reaction and record only 1/t, you have processed on the fly and the original times are gone. Write down what the instrument said. Turn it into something else in the next section, in daylight, with a calculator.

Qualitative observations are evidence

Qualitative data is everything you noticed but did not measure. Students treat it as a decorative sentence at the bottom of the page. It is actually the thing that will rescue your evaluation, because it is the only evidence you have about why a number came out wrong.

Here is that last one paying off. Suppose your first trial with magnesium is much slower than the rest. If you wrote “the ribbon looked dull and grey before it was added”, you can now argue that an oxide layer had to be removed before the acid could reach the metal. Without that sentence, the slow trial is just an unexplained number.

When the experiment fights back

Something will go wrong. That is not the problem. Pretending it did not is the problem, and it is also the easiest thing in the world for an assessor to spot, because the data stops making sense.

🧩 What to do the moment it goes wrong

  1. Notice. Look up from the apparatus and name what just happened.
  2. Write it down now, in the lab book, while you can still remember the detail.
  3. Respond — dilute the acid, run an extra trial, change the timing point.
  4. Report it in your method, saying what you changed and why you changed it.
A PROBLEM IS NOT A DISASTERan unrecorded problem isNOTICERECORDRESPONDREPORTthe reaction wasover before thestopwatch startedwrite it in the labbook the momentthat it happensdilute the acid sothe rate becomesmeasurable againsay what changedand why, insidethe methodresponding well to a problem is a skill being assessedso the fix belongs in the report, not quietly in the bin
The chain only breaks at step two. Everything after it depends on there being a written note made at the time, rather than a memory reconstructed a fortnight later.
What happensWhat to do about it
The reaction is over almost instantlyDilute a reactant or cool the mixture until the time is long enough to measure, then say in the method that you did and why.
The reaction is far too slow to timeRaise the concentration, warm the mixture or increase the surface area — and check the change has not broken one of your controlled variables.
One trial is wildly out of lineKeep it in the raw table. Run a fourth trial. You will exclude the outlier later, but only after you have justified it.
The endpoint colour creeps in slowlyNote exactly what you judged the endpoint to be, and use the same judgement every time. This becomes a real limitation in your evaluation.
WORKED EXAMPLE

A student’s raw data table contains one row: “Titre 3 = 21.5 cm3 (±0.1)”. Identify three separate faults and write the row out correctly.

Fault 1: it is not raw A titre is the final reading minus the initial reading, so it has been calculated. Both burette readings should appear instead. Fault 2: wrong precision A burette is read to two decimal places, with the last digit a 0 or a 5. Writing 21.5 pretends the burette was ten times worse than it is. Fault 3: the uncertainty is in the cell It belongs in the column header, where it applies to every value in that column at once. raw table row: Trial 3 | 0.30 | 21.80 with headers reading “Initial burette reading / cm³ (±0.05)” and “Final burette reading / cm³ (±0.05)”.
WORKED EXAMPLE

A student needs about 0.2 g of magnesium and has a balance reading to 0.01 g. They record “0.2 g”. Explain what is wrong, and suggest one change to the method that would improve the result more than better recording would.

The recording fault The balance supplied a second decimal place and it was discarded. The mass should be written as 0.20 g. Why it matters numerically ±0.01 g on 0.20 g = 5.0% uncertainty That single measurement is now the biggest source of uncertainty in the whole experiment. The better fix Use a larger sample. The same balance weighing 1.50 g gives only 0.67% — the uncertainty of the instrument is fixed, so make the quantity bigger. weigh more, and write every digit the balance gives
WORKED EXAMPLE

At 50 °C, three trials give times of 18.9 s, 30.2 s and 19.1 s. Describe exactly what the student should do next, and what they must not do.

What must not happen The 30.2 s result is not erased and not quietly replaced. Deleting data is the one thing that cannot be recovered from. Step 1: record and note Keep 30.2 s in the raw table and write a note beside it, for example that the stopwatch was started late because the flask was still being swirled. Step 2: run a fourth trial Under the same conditions. If it returns about 19 s, you now have three concordant results and one identified outlier. Step 3: leave the decision for later exclude it when processing, with a written justification You are allowed to leave an anomaly out of your mean. You are not allowed to leave it out of your report.

💡 Exam tip

⚠️ Common mix-up

Up next: Processing Data — you now have a page of honest numbers. The next page turns them into a single result, and carries the uncertainty along with it so the result means something.

Want this explained one-to-one?

Book a free session with an experienced IB Chemistry tutor and get your trickiest topics made simple.

Book a Free Session →

Subscribe to our newsletter

Get free IB notes, exam tips and new resources in your inbox.

We will ask you to confirm by email. Unsubscribe any time.